Description

Advanced features – 9202B Pulse Isolator

  • Configuration and monitoring by way of detachable display front (PR 4500).
  • Selection of direct or inverted function for each channel via PR 4500.
  • Advanced monitoring of internal communication and stored data.
  • Optional redundant supply via power rail and/ or separate supply.
  • SIL 2 functionality is optional and must be activated in a menu point.

Application

  • 9202B Pulse Isolator can be mounted in the safe area or in zone 2 / Cl. 1 div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including mining / Class I/II/III, Div. 1, Gr. A-G.
  • Pulse isolator for transmission of signals to the safe area from NAMUR sensors and mechanical switches installed in the hazardous area.
  • Monitoring of error events and cable breakage via the individual status relay and/or a collective electronic signal via the power rail.
  • The 9202B Pulse Isolator has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
  • Suitable for the use in systems up to Performance Level “d” according to ISO-13849.

Technical characteristics

  • 1 green and 2 yellow/red front LEDs indicate operation status and malfunction.
  • 2.6 kVAC galvanic isolation between input, output and supply.

Mounting

  • The devices can be mounted vertically or horizontally without distance between neighbouring units.

Datasheet

Manual

Environmental Conditions – 9202B Pulse Isolator

Operating temperature-20°C to +60°C
Storage temperature-20°C to +85°C
Calibration temperature20…28°C
Relative humidity< 95% RH (non-cond.)
Protection degreeIP20
Installation inPollution degree 2 & meas. / overvoltage cat. II

Mechanical specifications

Dimensions (HxWxD)109 x 23.5 x 104 mm
Dimensions (HxWxD) w/ PR 4500109 x 23.5 x 131 mm
Weight approx.170 g
DIN rail typeDIN EN 60715/35 mm
Wire size0.13…2.08 mm2 AWG 26…14 stranded wire
Screw terminal torque0.5 Nm
VibrationIEC 60068-2-6
2…13.2 Hz±1 mm
13.2…100 Hz±0.7 g

Common specifications

Supply

Supply voltage19.2…31.2 VDC
Fuse400 mA SB / 250 VAC
Max. required power≤ 1.1 W…≤ 1.3 W / ≤ 1.5 W…≤ 1.9 W (1 / 2 ch.)
Max. power dissipation, 1 / 2 ch.≤ 1.2 W / ≤ 1.6…1.8 W

Isolation voltage

Test /working: Input to any2.6 kVAC / 300 VAC reinforced isolation
Analog output to supply2.6 kVAC / 300 VAC reinforced isolation
Output 1 to output 21.5 kVAC / 150 VAC reinforced isolation
Status relay to supply1.5 kVAC / 150 VAC reinforced isolation

Auxiliary supplies

NAMUR supply8 VDC / 8 mA
ProgrammingPR 4500 communication interfaces
Response time for cable fault< 200 ms

Input specifications

Sensor typesNAMUR according to EN 60947-5-6 / mechanical contact
Frequency range0…5 kHz
Min. pulse length> 0.1 ms
Input resistanceNom. 1 kΩ
Trig level, signal< 1.2 mA, > 2.1 mA
Trig level, cable fault< 0.1 mA, > 6.5 mA

Output specifications

Relay output

Max. switching frequency20 Hz
Max. voltage250 VAC / 30 VDC
Max. current2 AAC / 2 ADC
Max. AC power500 VA / 60 W

Status relay

Max. voltage125 VAC / 110 VDC
Max. current0.5 AAC / 0.3 ADC
Max. AC power62.5 VA / 32 W

NPN output

Max. switching frequency5 kHz
Min. pulse length> 0.1 ms
Max. load, current / voltage80 mA / 30 VDC
Max. voltage drop at 80 mA2.5 VDC

Observed authority requirements

LVD2014/35/EU & UK SI 2016/1101
EMC2014/30/EU & UK SI 2016/1091
ATEX2014/34/EU & UK SI 2016/1107
RoHS2011/65/EU & UK SI 2012/3032
EACTR-CU 020/2011
EAC ExTR-CU 012/2011
EAC LVDTR-CU 004/2011

Approvals – 9202B Pulse Isolator

ATEXKEMA 07ATEX0146 X
IECExKEM 06.0039X
UKEXDEKRA 21UKEX0179X DEKRA 23UKEX0105X
c FM usFM19US0055X / FM19CA0028X
INMETRODEKRA 23.0007X
c UL us, UL 61010-1E314307
c UL us, UL 913E233311 (only 9202xxx-U9)
CCC2020322309003424
KCs21_AV4BO_0179X / 21_AV4BO_0180X (only 9202Bxx-KCs)
EAC ExEAEU KZ 7500361.01.01.08756
DNV MarineTAA00000JD
ClassNKTA24034M
SILSIL 2 certified & fully assessed acc. to IEC 61508

Reliable Pulse Signal Isolation for Hazardous Areas

The PR Electronics 9202B Pulse Isolator is a high-performance, intrinsically safe device designed to ensure accurate pulse signal transmission in hazardous environments. Engineered for superior galvanic isolation and signal integrity, the 9202B is essential for process automation and safety-critical applications.

Key Features:

  • Intrinsically Safe (Ex) Certified – Ensures safe operation in explosive atmospheres, meeting international safety standards.
  • Precise Pulse Signal Isolation – Provides accurate transmission of digital pulse signals while preventing interference.
  • Advanced Galvanic Isolation – 2.6 kVAC isolation between input, output, and power supply, protecting against electrical noise and ground loops.
  • Flexible Signal Compatibility – Supports NAMUR, mechanical contacts, and NPN/PNP transistor sensors.
  • Configurable Output Modes – Enables seamless integration into a wide range of industrial control systems.
  • Compact and DIN-Rail Mountable – Space-saving design for easy installation in industrial environments.

Applications:

The PR Electronics 9202B Pulse Isolator is ideal for industries requiring safe and reliable pulse signal transmission, including:

  • Oil & Gas
  • Chemical and Pharmaceutical Manufacturing
  • Industrial Automation in Hazardous Zones
  • Power Plants and Utilities
  • Process Control and Safety Systems

Why Choose the PR Electronics 9202B?

The 9202B Pulse Isolator offers best-in-class intrinsic safety, galvanic isolation, and signal accuracy, making it the preferred choice for hazardous industrial applications. Its robust design and flexible configuration options ensure seamless operation in demanding environments.

Optimize Your Pulse Signal Transmission Today

Enhance the safety and efficiency of your industrial processes with the PR Electronics 9202B Pulse Isolator. Contact us today for detailed specifications, pricing, and expert support.