Description
Applications
6437A HART 7 temperature transmitter – PR Electronics
- Temperature measurement of a wide range of TC and RTD types.
- Conversion of wide span linear resistance and potentiometer inputs to 4…20 mA.
- Conversion of bipolar mV signals to 4…20 mA.
- Integration into asset management schemes.
- Critical applications requiring superior accuracy and/or sensor redundancy and drift detection.
Technical characteristics
- True dual input transmitter, accepts the widest range of dual input combinations.
- Sensor redundancy – output automatically switches to secondary sensor in event of primary sensor failure, maintaining uptime.
- Sensor drift detection – alerts when sensor differential exceeds user-defined limits, for maintenance optimization.
- Dynamic variable mapping for process data in addition to the primary variable e.g. dual input features such as average, differential and min./max. tracking.
- Groundbreaking digital and analog signal accuracy over full input span and ambient conditions.
- Extensive sensor matching including Callendar Van Dusen and custom linearizations.
- Programmable input limits with runtime metering ensure maximum process traceability and sensor out of range protection.
- IEC 61508 : 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.
- 6437xxSx is suitable for the use in systems up to Performance Level “d” according to ISO-13849.
- Meets NAMUR NE21, NE43, NE44, NE89 and NE107 compliant diagnostics information.
Mounting / installation / programming
- DIN rail mounting with up to 84 inputs per meter.
- Configuration via PReset using PR5909 Loop Link /HART modem, or by Asset Management tool (e.g. Pactware, AMS, HART communicator).
- The 6437A can be mounted in zone 2 and zone 22 / Class I, Division 2, Groups A, B, C, D.
Environmental Conditions – 6437A HART 7 Temperature Transmitter
Operating temperature | -50°C to +85°C (standard) -40°C to +80°C (SIL) |
Storage temperature | -50°C to +85°C |
Calibration temperature | 23…25°C |
Relative humidity | < 99% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
Weight (single input / dual input) | 150 g / 160 g |
Wire size | 0.13…2.08 mm2 AWG 26…14 stranded wire |
DIN rail type | DIN EN 60715/35 mm |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2…25 Hz | ±1.6 mm |
25…100 Hz | ±4 g |
Common specifications
Supply | |
Supply voltage | 7.5*…48** VDC |
Power dissipation, per channel | ≤ 850 mW |
Additional min. supply voltage when using test terminals | 0.8 V |
Min. load resistance at >37 V supply | (Vsupply – 37) / 23 mA |
Isolation voltage | |
Isolation voltage, test / working | 2.5 kVAC / 55 VAC |
Response time | |
Response time | 75 ms |
Programmable damping | 0…60 s |
Polarity protection | All inputs and outputs |
Warm-up time | < 5 min. |
Start-up time | < 2.75 s |
Programming | Loop Link & HART |
Write protection | Jumper or software |
Signal / noise ratio | > 60 dB |
Long-term stability, better than | ±0.05% of span / year (±0.18% of span / 5 years) |
Signal dynamics, input | 24 bit |
Signal dynamics, output | 18 bit |
Effect of supply voltage change | < 0.005% of span / VDC |
Accuracy | See manual for details |
EMC immunity influence | < ±0.1% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% |
Input specifications
RTD input | |
RTD type | Pt10…10000, Ni10…10000, Cu5…1000 |
Basic accuracy, e.g. Pt100 | ≤ ±0.04°C |
Cable resistance per wire | 50 Ω (max.) |
Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
Sensor current | < 0.15 mA |
Sensor error detection | None, Shorted, Broken, Shorted or Broken |
TC input | |
Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
Basic accuracy, e.g. TC K | ≤ ±0.25°C |
Cold junction compensation (CJC) | Constant, internal or external via a Pt100 or Ni100 sensor |
Sensor error detection | None, Shorted, Broken, Shorted or Broken |
Linear resistance input | |
Measurement range / min. range (span) | 0 Ω…100 kΩ / 25 Ω |
Cable resistance per wire (max.) | 50 Ω |
Sensor current | < 0.15 mA |
Sensor error detection | None, Broken |
Potentiometer input | |
Potentiometer min….max. | 10 Ω…100 kΩ |
Measurement range / min. range (span) | 0…100% / 10% |
Cable resistance per wire (max.) | 50 Ω |
Sensor current | < 0.15 mA |
Sensor error detection | None, Shorted, Broken, Shorted or Broken |
mV input | |
Measurement range | -800…+800 mV (bipolar) -100…1700 mV |
Min. measurement range (span) | 2.5 mV |
Input resistance | 10 MΩ |
Sensor error detection | None, Broken |
Output specifications
Common output specifications | |
Normal range, programmable | 3.8…20.5 / 20.5…3.8 mA |
Extended range (output limits), programmable | 3.5…23 / 23…3.5 mA |
Basic accuracy | ≤ ±1.6 μA (0.01% of full output span) |
Updating time | 10 ms |
Load (@ current output) | ≤ (Vsupply -7.5)/0.023 [Ω] |
Load stability | < 0.01% of span / 100 Ω |
Sensor error indication | Programmable 3.5…23 mA |
NAMUR NE 43 Upscale/Downscale | > 21 mA / < 3.6 mA |
HART protocol revisions | HART 7 and HART 5 |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 2014/30/EU |
RoHS | 2011/65/EU & UK SI 2012/3032 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals – 6437A HART 7 Temperature Transmitter
ATEX | DEKRA 18ATEX0135X |
IECEx | IECEx DEK. 16.0029X |
CSA | CSA 16.70066266 |
c FM us | FM16US0287X / FM16CA0146X |
INMETRO | DEKRA 23.0002X |
NEPSI | GYJ23.1253X |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
EU RO MR Type Approval | MRA0000023 |
SIL | SIL 2 / SIL 3 certified & fully assessed acc. to IEC 61508 |
Enhance Your Temperature Measurement with PR Electronics
The 6437A HART 7 Temperature Transmitter by PR Electronics delivers high-precision temperature measurements with enhanced digital communication. Designed for industrial applications, this transmitter ensures reliability, accuracy, and seamless integration into control systems.
Key Features and Benefits
- HART 7 Protocol Compatibility – Advanced diagnostics, remote configuration, and improved response times.
- High Accuracy & Stability – Precise temperature measurements with minimal drift over time.
- Universal Sensor Input – Supports RTDs, thermocouples, and resistance/voltage inputs.
- Loop-Powered (2-Wire Design) – Reduces wiring complexity and enhances energy efficiency.
- Robust Industrial Design – Operates in harsh environments with high resistance to electrical noise and extreme temperatures.
Why Choose PR Electronics?
PR Electronics is a leader in industrial signal conditioning, offering innovative temperature transmitters with superior performance. The 6437A HART 7 Temperature Transmitter is engineered for optimal integration into modern process automation systems, making it an ideal choice for industries like oil & gas, chemical processing, and manufacturing.
Applications – 6437A HART 7 Temperature Transmitter
- Process Automation
- Power Generation
- Food & Beverage
- Chemical & Pharmaceutical Industries
- HVAC & Environmental Monitoring
Get Started Today
Upgrade your temperature monitoring with the PR Electronics 6437A HART 7 Temperature Transmitter. Contact us today for more information or a customized solution tailored to your industry needs.