Description

Application – 5337A HART Temperature Transmitter

  • Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
  • HART communication and 4…20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
  • Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
  • Amplification of bipolar mV signals to standard 4…20 mA current signals.
  • Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.

Technical characteristics

  • HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
  • The HART 7 protocol offers:
    ∙ Long Tag numbers of up to 32 characters.
    ∙ Enhanced Burst Mode and Event notification with time stamping.
    ∙ Device variable and status mapping to any dynamic variable PV, SV, TV or QV.
    ∙ Process signal trend measurement with logs and summary data.
    ∙ Automatic event notification with time stamps.
    ∙ Command aggregation for higher communication efficiency.
  • 5337A is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.
  • Continuous check of vital stored data.
  • Meeting the NAMUR NE21 recommendations, the 5337 HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the 5337 meets NAMUR NE43 and NE89 recommendations.

Mounting / installation

  • For DIN form B sensor head or DIN rail mounting via the PR fitting type 8421.
  • Configuration via standard HART communication interfaces or by PR 5909 Loop Link.

Datasheet

Manual

Environmental Conditions – 5337A HART Temperature Transmitter

Operating temperature-40°C to +85°C
Calibration temperature20…28°C
Relative humidity< 95% RH (non-cond.)
Protection degree (encl./terminal)IP68 / IP00

Mechanical specifications

DimensionsØ 44 x 20.2 mm
Weight approx.50 g
Wire size1 x 1.5 mm2 stranded wire
Screw terminal torque0.4 Nm
VibrationIEC 60068-2-6
2…25 Hz±1.6 mm
25…100 Hz±4 g

Common specifications

Supply

Supply voltage8.0…35 VDC

Isolation voltage

Isolation voltage, test / working1.5 kVAC / 50 VAC

Response time

Response time (programmable)1…60 s
Voltage drop8.0 VDC
Signal / noise ratio> 60 dB
ProgrammingLoop Link & HART
AccuracyBetter than 0.05% of selected range
Signal dynamics, input22 bit
Signal dynamics, output16 bit
EMC immunity influence< ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst< ±1% of span

Input specifications

Common input specifications

Max. offset50% of selected max. value

RTD input

RTD typePt50/100/200/500/1000; Ni50/100/120/1000
Cable resistance per wire5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
Sensor currentNom. 0.2 mA

TC input

Thermocouple typeB, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation (CJC)Constant, internal or external via a Pt100 or Ni100 sensor

Voltage input

Measurement range-800…+800 mV
Min. measurement range (span)2.5 mV
Input resistance10 MΩ

Output specifications

Current output

Signal range4…20 mA
Min. signal range16 mA
Load (@ current output)≤ (Vsupply – 8) / 0.023 [Ω]
Sensor error indicationProgrammable 3.5…23 mA
NAMUR NE43 Upscale/Downscale23 mA / 3.5 mA

Common output specifications

Updating time440 ms
HART protocol revisionsHART 7 and HART 5

I.S. / Ex marking

ATEXII 3 G Ex nA [ic] IIC T6…T4 Gc, II 3 G Ex ec [ic] IIC T6…T4 Gc, II 3 G Ex ic IIC T6…T4 Gc, II 3 D Ex ic IIIC Dc
IECExEx nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc
CSACl. I, Div. 2, Gp. A, B, C, D T6…T4, Ex nA[ic] IIC T6…T4 Gc
INMETROEx ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc

Observed authority requirements

EMC2014/30/EU & UK SI 2016/1091
ATEX2014/34/EU & UK SI 2016/1107
RoHS2011/65/EU & UK SI 2012/3032
EACTR-CU 020/2011
EAC ExTR-CU 012/2011

Approvals – 5337A HART Temperature Transmitter

DNV MarineTAA0000101
ATEXDEKRA 20ATEX0109X
IECExDEK 20.0063X
CSA1125003
INMETRODEKRA 23.0011X
EAC ExEAEU KZ 7500361.01.01.08756
SILHardware assessed for use in SIL applications

The PR Electronics 5337A HART Temperature Transmitter is a versatile, high-precision device designed to convert various sensor inputs into a standardized 4…20 mA analog current signal, ensuring accurate and reliable temperature measurements across diverse industrial applications.

Key Features – 5337A HART Temperature Transmitter

  • Universal Input Compatibility: Supports a wide range of sensors, including:

    • RTDs: Pt100, Ni100, and others.
    • Thermocouples (TC): Types B, E, J, K, L, N, R, S, T, U, W3, W5, and LR.
    • Linear Resistance: 0 to 7000 Ω.
    • Millivolt Signals: -800 to 800 mV.
  • Dual Sensor Input: Features two analog inputs, allowing for measurements of individual, differential, or average temperatures from two RTD or TC sensors.

  • HART Protocol: Incorporates HART communication, enabling remote configuration and monitoring, enhancing integration with modern control systems.

  • High Measurement Accuracy: Delivers exceptional precision with an accuracy of ±0.05% of span, making it suitable for critical process control applications.

  • Galvanic Isolation: Features 1.5 kVAC galvanic isolation, enhancing signal integrity and protecting against electrical interference.

  • Programmable Sensor Error Detection:  5337A HART Temperature Transmitter allows customization of sensor error values, enabling prompt identification and correction of measurement discrepancies.

  • Flexible Mounting Options: Designed for installation in DIN form B sensor heads or DIN rail mounting via the PR fitting type 8421, accommodating various industrial setups.

Technical Specifications – 5337A HART Temperature Transmitter

  • Output Signal: Standard 4…20 mA current loop, compliant with NAMUR NE43 standards (3.5/23 mA).

  • Supply Voltage: Operates within a range of 8 to 35 VDC, ensuring compatibility with different power sources.

  • Operating Temperature Range: Designed to function reliably in ambient temperatures from -40 to +85°C, suitable for harsh industrial environments.

  • Dimensions and Weight: Compact design with dimensions of Ø 44 x 20.2 mm and a weight of approximately 50 grams, facilitating easy integration into existing systems.

Applications:

  • Temperature Measurement: Linearized temperature measurement with RTD or thermocouple sensors, ensuring accurate monitoring in processes where temperature control is critical.

  • Signal Conversion: Converting linear resistance or bipolar mV signals to standard 4…20 mA current signals, facilitating integration with various industrial instrumentation.

Why Choose the PR Electronics 5337A HART Temperature Transmitter?

Integrating the 5337A HART Temperature Transmitter into your temperature measurement and control systems offers:

  • Versatility: Universal sensor compatibility and dual input functionality allow for seamless integration across diverse applications.

  • Precision: High measurement accuracy ensures reliable data for critical process decisions.

  • Advanced Communication: HART protocol facilitates remote configuration and monitoring, enhancing operational efficiency.

  • Durability: Robust design and wide operating temperature range make it suitable for challenging industrial environments.

You may also like…

PR 5334A Temperature Transmitter

$139

1 in stock
Fast Delivery
PR 5333A Temperature Transmitter

$127

Available on backorder
Fast Delivery

Related Products

PR 4114 Universal Transmitter

$223

7 Sold 10 in stock
Fast Delivery
PR 6437D HART 7 Temperature Transmitter

Available on backorder
Fast Delivery
PR 3101 TC converter

$125

1 in stock
Fast Delivery