Description

Advanced features – 5114B Programmable Transmitter

  • The 5114 transmitter can be configured using the PReset software and the Loop Link communications unit.

Application

  • Jumper selectable inputs for current/voltage or temperature.
  • Programmable current (0…100 mA) and voltage (0…250 VDC) inputs.
  • Linearized, electronic temperature measurement.
  • Conversion of linear resistance variation e.g, from solenoids and butterfly valves or linear movements with attached potentiometer.
  • 17.1 VDC loop and 2.5 VDC potentiometer supplies.
  • Automatic 4- / 3-wire or programmable 2-wire cable compensation.
  • Configurable sensor error detection including NAMUR NE43.

Technical characteristics

  • Active or Passive current output and selectable voltage output.
  • Separation of circuits in PELV/SELV installations.
  • I.S. barrier for temperature sensors, potentiometers, and current / voltage signals.
  • I.S. barrier with I.S. power supply for 2-wire transmitters in zone 0, 1, 2, 20, 21 and 2.

Note

  • Not suitable for new installations requiring certification to the latest ATEX standards – see ATEX certificate DEMKO 99ATEX124571 and EU Declaration of Conformity for details.

Datasheet

Manual

Environmental Conditions – 5114B Programmable Transmitter

Operating temperature-20°C to +60°C
Calibration temperature20…28°C
Relative humidity< 95% RH (non-cond.)
Protection degreeIP20

Mechanical specifications

Dimensions (HxWxD)109 x 23.5 x 130 mm
Weight approx.225 g
DIN rail typeDIN EN 60715/35 mm
Wire size0.13…2.08 mm2 AWG 26…14 stranded wire
Screw terminal torque0.5 Nm
VibrationIEC 60068-2-6
2…13.2 Hz±1 mm
13.2…100 Hz±0.7 g

Common specifications

Supply

Supply voltage, universal21.6…253 VAC, 50…60 Hz or 19.2…300 VDC
Fuse400 mA SB / 250 VAC
Max. required power2.1 W / 2.8 W (1 / 2 ch.)
Max. power dissipation2.0 W

Isolation voltage

Isolation voltage, test / working3.75 kVAC / 250 VAC
PELV/SELVIEC 61140

Response time

Temperature input, programmable (0…90%, 100…10%)400 ms…60 s
mA / V input (programmable)250 ms…60 s

Auxiliary supplies

2-wire supply (pin 44…42 and 54…52)28…17.1 VDC / 0…20 mA
ProgrammingLoop Link
Signal / noise ratioMin. 60 dB (0…100 kHz)
AccuracyBetter than 0.05% of selected range
Updating time115 ms (temperature input) 75 ms (mA / V / mV input)
Signal dynamics, input22 bit
Signal dynamics, output16 bit
Auxiliary voltages: Reference voltage2.5 VDC ±0.5% / 15 mA
EMC immunity influence< ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst< ±1% of span

Input specifications

Common input specifications

Max. offset50% of selected max. value

RTD input

RTD typePt100, Ni100, lin. R
Cable resistance per wire10 Ω (max.)
Sensor currentNom. 0.2 mA
Effect of sensor cable resistance (3-/4-wire)< 0.002 Ω / Ω

TC input

Thermocouple typeB, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation (CJC)< ±1.0°C
Sensor error currentNom. 30 μA
Sensor error detectionYes

Current input

Measurement range0…100 mA
Min. measurement range (span)4 mA
Input resistance: Supplied unitNom. 10 Ω + PTC 10 Ω
Input resistance: Non-supplied unitRSHUNT = ∞, VDROP < 6 V

Voltage input

Measurement range0…250 VDC -150…+150 mV
Min. measurement range (span)5 mV
Input resistanceNom. 10 MΩ (≤ 2.5 VDC) Nom. 5 MΩ (> 2.5 VDC)
Nom. 10 MΩ (mV input)

Output specifications

Current output

Signal range0…20 mA
Min. signal range10 mA
Load (@ current output)≤ 600 Ω
Load stability≤ 0.01% of span / 100 Ω
Current limit≤ 28 mA
Sensor error indicationProgrammable 0…23 mA
NAMUR NE43 Upscale/Downscale23 mA / 3.5 mA

Passive 2-wire mA output

Signal range4…20 mA
Load stability≤ 0.01% of span / 100 Ω
Max. external 2-wire supply29 VDC
Effect of external 2-wire supply voltage variation< 0.005% of span / V

Voltage output

Signal range0…10 VDC
Min. signal range500 mV
Load (@ voltage output)≥ 500 kΩ
of span= of the presently selected range

Observed authority requirements

EMC2014/30/EU
LVD2014/35/EU
ATEX2014/34/EU
RoHS2011/65/EU
EACTR-CU 020/2011
EAC ExTR-CU 012/2011

Approvals – 5114B Programmable Transmitter

ATEXDEMKO 99ATEX124571, II (1) GD [EEx ia] IIC
EAC ExEAEU KZ 7500361.01.01.08756
DNV MarineTAA0000101

High-Performance Signal Conditioning for Industrial Applications

The PR Electronics 5114B Programmable Transmitter is a high-accuracy, versatile signal conditioning device designed to enhance industrial automation and process control. Engineered for seamless integration, the 5114B ensures precise signal conversion, isolation, and transmission, making it an essential component for demanding environments.

Key Features:

  • Universal Signal Compatibility – Supports a wide range of input signals, including mA, voltage, potentiometer, and temperature sensors (RTD and TC).
  • Flexible Output Options – Provides analog current/voltage output and relay switching for maximum adaptability.
  • Advanced Galvanic Isolation – Offers 2.3 kVAC isolation between input, output, and power supply, ensuring optimal signal integrity and protection against electrical interference.
  • Programmable via PC and PR 4501 – Enables easy parameter configuration, reducing setup time and enhancing usability.
  • Fast Response Time – High-speed signal processing for real-time monitoring and control.
  • Compact and Durable Design – DIN-rail mountable with robust construction suitable for industrial settings.

Applications:

Ideal for industries requiring precise signal conditioning, the PR Electronics 5114B is used in:

  • Industrial automation
  • Process control systems
  • Power plants and utilities
  • Chemical and pharmaceutical manufacturing
  • Machine monitoring and safety applications

Why Choose the PR Electronics 5114B?

The 5114B Programmable Transmitter is designed for professionals who demand accuracy, reliability, and flexibility in their signal conditioning solutions. With its intuitive programming, robust isolation, and broad signal compatibility, it is an excellent choice for optimizing performance in critical applications.

Enhance Your Industrial Automation Today

Invest in the PR Electronics 5114B Programmable Transmitter for superior signal reliability and performance. Contact us now for pricing, specifications, and expert support.