Application – 5105B Ex isolated driver
- Safety barrier for current signals transmitted to I/P converters and displays mounted in hazardous area.
- Safety barrier for analog current / voltage signals transmitted to hazardous area.
- 1 : 1 or signal conversion of analog current / voltage signals.
Technical characteristics
- The 20 factory-calibrated measurement ranges in the 5105B can be selected by the internal DIP-switches without the need for a recalibration. Special measurement ranges can be delivered.
- PR5105B is based on microprocessor technology for gain and offset. The analog signal is transmitted at a response time of less than 25 ms.
- Inputs, outputs, and supply are floating and galvanically separated.
Mounting / installation
- Mounted vertically or horizontally on a DIN rail. By way of the 2-channel version up to 84 channels per meter can be mounted.
Note
- Not suitable for new installations requiring certification to the latest ATEX standards – see ATEX certificate DEMKO 99ATEX126014 and EU Declaration of Conformity for details.
Environmental Conditions – 5105B Ex isolated driver
Operating temperature | -20°C to +60°C |
Calibration temperature | 20…28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 130 mm |
Weight approx. | 225 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13…2.08 mm2 AWG 26…14 stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2…13.2 Hz | ±1 mm |
13.2…100 Hz | ±0.7 g |
Common specifications
Supply | |
Supply voltage, universal | 21.6…253 VAC, 50…60 Hz or 19.2…300 VDC |
Fuse | 400 mA SB / 250 VAC |
Max. required power | ≤ 2 W (2 channels) |
Internal power dissipation | ≤ 2 W (2 channels) |
Isolation voltage | |
Isolation voltage, test / working | 3.75 kVAC / 250 VAC |
PELV/SELV | IEC 61140 |
Response time | |
Response time (0…90%, 100…10%) | < 25 ms |
Signal / noise ratio | Min. 60 dB (0…100 kHz) |
Accuracy | Better than 0.1% of sel. range |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications | |
Max. offset | 20% of max. value |
Current input | |
Measurement range | 0…20 mA |
Min. measurement range (span) | 16 mA |
Input resistance | Nom. 10 Ω + PTC 10 Ω |
Voltage input | |
Measurement range | 0…10 VDC |
Min. measurement range (span) | 8 VDC |
Input resistance | > 2 MΩ |
Output specifications
Current output | |
Signal range | 0…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ 770 Ω |
Load stability | ≤ 0.01% of span / 100 Ω |
Current limit | ≤ 28 mA |
Voltage output | |
Signal range | 0…1 VDC / 0…10 VDC |
Min. signal range | 0.8 VDC / 8 VDC |
Load (@ voltage output) | ≥ 500 kΩ |
of span | = of the presently selected range |
Observed authority requirements
EMC | 2014/30/EU |
LVD | 2014/35/EU |
EAC | TR-CU 020/2011 |
Approvals – 5105B Ex isolated driver
ATEX | DEMKO 99ATEX126014, II (1) GD [EEx ia] IIC |
c UL us, UL 913 | E233311 |
DNV Marine | TAA0000101 |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
Reliable Intrinsically Safe Signal Transmission
The PR Electronics 5105B Ex Isolated Driver is a high-performance interface module designed to ensure safe and precise signal transmission in hazardous areas. Engineered for applications requiring intrinsic safety, this isolated driver provides robust galvanic isolation and reliable signal conversion, making it ideal for process automation in explosive environments.
Key Features:
- Intrinsically Safe (Ex) Certified – Designed for hazardous locations, ensuring safe operation in explosive atmospheres.
- Wide Input Signal Compatibility – Supports analog signals, including current and voltage inputs.
- High-Performance Galvanic Isolation – Provides 2.6 kVAC isolation between input, output, and power supply, preventing signal interference and electrical faults.
- Configurable Output – Offers both active and passive output modes for maximum flexibility in system integration.
- Fast and Precise Signal Transmission – Ensures low response time for real-time control applications.
- Compact DIN-Rail Mountable Design – Space-saving and durable construction suited for industrial environments.
Applications:
The PR Electronics 5105B Ex Isolated Driver is essential for industries that require intrinsically safe signal processing, including:
- Oil & Gas
- Chemical and Pharmaceutical Manufacturing
- Power Plants and Utilities
- Industrial Automation in Hazardous Zones
- Process Control Systems
Why Choose the PR Electronics 5105B?
With its intrinsically safe certification, advanced galvanic isolation, and versatile output options, the 5105B Ex Isolated Driver is a trusted solution for maintaining safety and reliability in hazardous environments. It provides superior protection against electrical interference, ensuring optimal performance in critical applications.
Secure Your Process Control with the 5105B Ex Isolated Driver
Upgrade your hazardous area signal transmission with the PR Electronics 5105B Ex Isolated Driver. Contact us today for detailed specifications, pricing, and expert support.