Description
Application – 5104B Ex repeater power supply
- Supply voltage and safety barrier for 2-wire transmitters mounted in a hazardous area.
- Safety barrier for analog current / voltage signals from a hazardous area.
- 1 : 1 or signal conversion of analog current / voltage signals.
Technical characteristics
- The 20 factory-calibrated measurement ranges in the 5104B can be selected by the internal DIP-switches without the need for recalibration. Special measurement ranges can be delivered.
- PR5104B is based on microprocessor technology for gain and offset. The analog signal is transmitted at a response time of less than 25 ms.
- Inputs, outputs, and supply are floating and galvanically separated.
- The output can be connected either as an active current / voltage transmitter or as a 2-wire transmitter.
Mounting / installation
- Mounted vertically or horizontally on a DIN rail. By way of the 2-channel version up to 84 channels per meter can be mounted.
Note
- Not suitable for new installations requiring certification to the latest ATEX standards – see ATEX certificate DEMKO 99ATEX126013 and Declaration of conformity for details.
Environmental Conditions – 5104B Ex repeater power supply
Operating temperature | -20°C to +60°C |
Calibration temperature | 20…28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 130 mm |
Weight approx. | 225 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13…2.08 mm2 AWG 26…14 stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2…13.2 Hz | ±1 mm |
13.2…100 Hz | ±0.7 g |
Common specifications
Supply | |
Supply voltage, universal | 21.6…253 VAC, 50…60 Hz or 19.2…300 VDC |
Fuse | 400 mA SB / 250 VAC |
Max. required power | ≤ 3 W (2 channels) |
Internal power dissipation | ≤ 2 W (2 channels) |
Isolation voltage | |
Isolation voltage, test / working | 3.75 kVAC / 250 VAC |
PELV/SELV | IEC 61140 |
Auxiliary supplies | |
2-wire supply (pin 44…42 and 54…52) | 28…17.1 VDC / 0…20 mA |
Response time | |
Response time (0…90%, 100…10%) | < 25 ms |
Signal / noise ratio | Min. 60 dB (0…100 kHz) |
Accuracy | Better than 0.1% of sel. range |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications | |
Max. offset | 20% of max. value |
Current input | |
Measurement range | 0…20 mA |
Min. measurement range (span) | 16 mA |
Input resistance | Nom. 10 Ω + PTC 10 Ω |
Voltage input | |
Measurement range | 0…10 VDC |
Min. measurement range (span) | 8 VDC |
Input resistance | > 2 MΩ |
Output specifications
Current output | |
Signal range | 0…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ 600 Ω |
Load stability | ≤ 0.01% of span / 100 Ω |
Current limit | ≤ 28 mA |
Passive 2-wire mA output | |
Effect of external 2-wire supply voltage variation | < 0.005% of span / V |
Voltage output | |
Signal range | 0…1 VDC / 0…10 VDC |
Min. signal range | 0.8 VDC / 8 VDC |
Load (@ voltage output) | ≥ 500 kΩ |
External loop supply | 29 VDC |
of span | = of the presently selected range |
Observed authority requirements
EMC | 2014/30/EU |
LVD | 2014/35/EU |
EAC | TR-CU 020/2011 |
Approvals – 5104B Ex repeater power supply
ATEX | DEMKO 99ATEX126013, II (1) GD [EEx ia] IIC |
c UL us, UL 913 | E233311 |
DNV Marine | TAA0000101 |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
Reliable Power Supply and Signal Transmission for Hazardous Areas
The PR Electronics 5104B Ex Repeater Power Supply is an intrinsically safe, high-performance power supply designed for hazardous environments. It ensures safe and reliable power and signal transmission to Ex-certified transmitters, making it an essential component for process automation in explosive atmospheres.
Key Features:
- Intrinsically Safe (Ex) Certified – Designed for hazardous locations, ensuring compliance with international safety standards.
- Reliable Power Supply for Ex Transmitters – Provides stabilized power to 2-wire transmitters in hazardous zones.
- High Galvanic Isolation – 2.6 kVAC isolation between input, output, and power supply, preventing ground loops and signal interference.
- Signal Repeating Capability – Transmits analog signals with high accuracy while ensuring full isolation.
- Configurable Active/Passive Output – Offers flexible integration into existing process control systems.
- Compact and DIN-Rail Mountable – Space-saving design ideal for industrial environments.
Applications:
The PR Electronics 5104B Ex Repeater Power Supply is widely used in industries requiring intrinsically safe signal transmission, including:
- Oil & Gas
- Chemical and Pharmaceutical Manufacturing
- Power Plants and Utilities
- Industrial Automation in Hazardous Zones
- Process Control Systems
Why Choose the PR Electronics 5104B?
The 5104B Ex Repeater Power Supply offers superior intrinsic safety, galvanic isolation, and signal reliability, ensuring optimal performance in hazardous environments. Its robust design and flexible configuration options make it a preferred choice for critical industrial applications.
Ensure Safe and Reliable Signal Transmission Today
Invest in the PR Electronics 5104B Ex Repeater Power Supply for enhanced safety and performance in hazardous areas. Contact us today for detailed specifications, pricing, and expert support.