PR 4184 Universal uni-bipolar signal transmitter
Application
- Fast < 20 ms response time for measuring signals produced by torque, position, current & acceleration sensors.
- User configurable bipolar or unipolar I/O means the 4184 is suitable for nearly any DC voltage or current conversion.
- Freely programmable between ±300 VDC and ±100 mA.
- The excitation source allows measurement of a 2-wire or 3-wire transmitter, or a potentiometer.
- Converts narrow bipolar inputs to wide bipolar or unipolar outputs, e.g., ±1 volt input = ±10 volt or 4…20 mA output.
- Configurable input limits control the output value for increased safety.
- ±20 VDC buffered voltage output for controlling devices like the PVG 32 valve (6…18 VDC).
- Designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
- Suitable for the use in systems up to Performance Level “d” according to ISO-13849.
Technical characteristics
- The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
- Possibility of output safety readback by selecting S4…20 mA output.
- The current output can drive up to 1000 Ohms, with an adjustable response time of 0.0…60.0 seconds.
- Exceptional mA output load stability of < 0.001% of span / 100 Ohm.
- Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
- Meets the NAMUR NE43 recommendations, allowing the control system to easily detect a sensor error.
- Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
Mounting / installation / programming
- Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
- Configuration, monitoring, 2-point process calibration and more are accomplished using PR’s 4500 series of detachable displays.
Environmental Conditions – PR 4184 Universal uni-bipolar signal transmitter
Operating temperature | -20°C to +60°C |
Storage temperature | -20°C to +85°C |
Calibration temperature | 20…28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
Dimensions (HxWxD) w/ PR 4500 | 109 x 23.5 x 131 mm |
Weight approx. | 155 g |
Weight incl. 4501 / 451x (approx.) | 170 g / 185 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13…2.08 mm2 AWG 26…14 stranded wire |
Screw terminal torque | 0.5 Nm |
Common specifications -PR 4184 Universal uni-bipolar signal transmitter
Supply | |
Supply voltage, universal | 21.6…253 VAC, 50…60 Hz or 19.2…300 VDC |
Max. required power | ≤ 2.5 W |
Internal power dissipation | ≤ 2.0 W |
Isolation voltage | |
Test voltage | 2.3 kVAC |
Working voltage | 250 VAC (reinforced) / 500 VAC (basic) |
Response time | |
Response time (0…90%, 100…10%) | < 20 ms |
Auxiliary supplies | |
2-wire loop supply | > 16 V @ 23 mA |
3-wire loop supply | > 18…< 28 V @ 23…0 mA |
Loop supply limitation | 27…35 mA avg., < 80 mA peak |
Reference voltage | 2.5 VDC ±0.5% |
Reference voltage, load | 0…15 mA |
Current limit, reference voltage | < 60 mA |
Programming | PR 4500 communication interfaces |
Signal dynamics, input | 24 bit |
Signal dynamics, output | 18 bit |
Signal / noise ratio | > 60 dB |
Bandwidth | > 40 Hz |
Accuracy | Better than 0.05% of selected range |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Conducted emission, cl. A | 150 kHz…10 MHz |
Input specifications – PR 4184 Universal uni-bipolar signal transmitter
Current input | |
Signal range | ±100 mA |
Programmable measurement ranges | 0…1, 0…5, 1…5, 0…20, 4…20, ±1, ±5, ±10, ±20, ±50, ±100 mA |
Custom configurable signal range | ±100 mA |
Min. measurement range (span) | 0.5 mA |
Input voltage drop | 0.6 V @ 20 mA nom. |
Voltage input | |
Signal range | ±300 VDC |
Programmable measurement ranges | 0…0.1, 0…1, 0.2…1, 0…2.5, 0…5, 1…5, 0…10, 2…10, 0…100, 0…300, ±0.1, ±1, ±2.5, ±5, ±10, ±100, ±300 V |
Custom configurable signal range | ±300 V |
Min. measurement range (span) | 25 mV |
Input resistance | Nom. 3 MΩ (> 2.5 VDC) Nom. > 10 MΩ (≤ 2.5 VDC) |
Potentiometer input | |
3-wire potentiometer input | 0…100% |
Reference voltage | 2.5 V |
Calibration resistance | 5 kΩ |
Min. potentiometer resistance | 200 Ω |
Output specifications – PR4184 Universal uni-bipolar signal transmitter
Current output | |
Signal range | 0…23 mA (unipolar) -23…+23 mA (bipolar) |
Custom config. output range | ±20 mA |
Min. signal range | 4 mA |
Load (@ current output) | ≤ 1000 Ω / ± 20 V @ ±20 mA |
Current limit | ≤ 28 mA (unipolar) ± 28 mA (bipolar) |
Load stability | ≤ 0.001% of span / 100 Ω |
Response time, programmable | 0.0…60.0 s |
Passive 2-wire mA output | |
Programmable ranges | 0…20 and 4…20 mA |
Ext. 2-wire loop supply range | 3.5…28.8 VDC |
Voltage output | |
Programmable signal ranges | 0/0.2…1; 0/1…5 ; 0/2…10 V ±1, ±5 and ±10 V Direct or Inverted action |
Load (@ voltage output) | ≥ 500 kΩ |
Response time, programmable | 0.0…60.0 s |
Shunted voltage output | |
Signal range | ± 1.2 V / ± 12 V |
Programmable standard ranges | 0…1, 0…2.5, 0…5, 1…5, 0…10, 2…10 V ±1, ±2.5, ±5, ±10 V |
Min. span | 0.8 V |
Custom config. output range | ±10 V |
Load, min. | > 500 kΩ |
Buffered voltage output | |
Signal range | ± 23 V |
Programmable standard ranges | 0…1, 0.2…1, 0…2.5, 0…5, 1…5, 0…10, 2…10, 0…20, 4…20; ±1, ±2.5, ±5, ±10, ±20 V |
Min. span | 0.8 V |
Custom config. output range | ±20 V |
Current limit | < 50 mA |
Load, min. | > 2 kΩ |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
LVD | 2014/35/EU & UK SI 2016/1101 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
Approvals – PR 4184 Universal uni-bipolar signal transmitter
c UL us, UL 508 | E248256 |
SIL | Hardware assessed for use in SIL applications |