Description

PR 4179 Universal AC / DC transmitter from PR Electronics with mA/Voltage output.

Application

  • The 0…5 AAC RMS range makes it possible to accurately measure a typical current transformer.
  • The 0…300 VAC RMS range allows accurate supply voltage monitoring.
  • The 4179 measures standard input ranges, and can be freely configured to customer-defined input range.
  • Converts narrow AC current / voltage inputs to wide bipolar or unipolar outputs, e.g. 0…1 VAC RMS input = ±10 volt or 4…20 mA output with a minimum span of 0.5 AAC RMS or 0.5 VAC RMS.
  • Configurable input limits control the output value for increased safety.
  • The 4179 has been designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
  • Suitable for the use in systems up to Performance Level “d” according to ISO-13849.

Technical characteristic – 4179 Universal AC / DC transmitter 

  • The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
  • Possibility of output safety feedback by selecting S4…20 mA output.
  • The current output can drive up to 800 Ohms, with an adjustable response time of 0.0…60.0 seconds.
  • Exceptional mA output load stability of <0.001% of span / 100 Ohm.
  • Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
  • Meets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.
  • Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
  • Excellent signal to noise ratio of > 60 dB.

Mounting / installation / programming – 4179 Universal AC / DC transmitter from PR Electronics

  • Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
  • Configuration, monitoring, 2-point process calibration and more are accomplished using PR’s 4500 series of detachable displays.
Data sheet

Environmental Conditions

Operating temperature-20°C to +60°C
Storage temperature-20°C to +85°C
Calibration temperature20…28°C
Relative humidity< 95% RH (non-cond.)
Protection degreeIP20
Installation inPollution degree 2 & meas. / overvoltage cat. II

Mechanical specifications

Dimensions (HxWxD)109 x 23.5 x 104 mm
Dimensions (HxWxD) w/ PR 4500109 x 23.5 x 131 mm
Weight approx.155 g
Weight incl. 4501 / 451x (approx.)170 g / 185 g
DIN rail typeDIN EN 60715/35 mm
Wire size0.13…2.08 mm2 AWG 26…14 stranded wire
Screw terminal torque0.5 Nm
VibrationIEC 60068-2-6
2…13.2 Hz±1 mm
13.2…100 Hz±0.7 g

Common specifications

Supply

Supply voltage, universal21.6…253 VAC, 50…60 Hz or 19.2…300 VDC
Max. required power1.6 W
Max. power dissipation – current measurement2.7 W
Max. power dissipation – voltage measurement1.6 W

Isolation voltage

Test voltage2.3 kVAC
Working voltage250 VAC (reinforced) / 500 VAC (basic)

Response time

Response time (0…90%, 100…10%)< 0.75 s
ProgrammingPR 4500 communication interfaces
Signal dynamics, input20 bit
Signal dynamics, output18 bit
Signal / noise ratio> 60 dB
Output referred common mode rejection ratio0.02 ppm / VHz
AccuracyBetter than 0.3% of selected range*
EMC immunity influence< ±0.5% of span*
Extended EMC immunity: NAMUR NE21, A criterion, burst< ±1% of span*
of span= of selected standard range

Input specifications – 4179 Universal AC / DC transmitter

Current input

Signal range0…5 AAC / 40…400 Hz
Maximum input limit6.00 AAC @ 40°C
Programmable measurement ranges0…0.5; 0…1; 0…2.5 & 0…5 AAC
Custom configurable signal range0…5 AAC /40…400 Hz
Min. measurement range (span)0.5 AAC
Input resistance< 0.042 Ω (incl. terminals)

Voltage input

Signal range0…300 VAC / 40…400 Hz
Programmable measurement ranges0…0.5, 0…1, 0…2.83, 0…5, 0…120, 0…230 & 0…300 VAC
Custom configurable signal range0…300 VAC / 40…400 Hz
Min. measurement range (span)0.5 VAC
Input resistanceNom. 3 MΩ || 100 pF

Output specifications – 4179 Universal AC / DC transmitter

Active unipolar and bipolar mA output

Programmable ranges0…20, 4…20 and S4…20 mA ±10 and ±20 mA
Direct or Inverted Action
Load (@ current output)≤ 800 Ω
V-curve function, active signals, 100-0-100%20-0-20 mA

Passive 2-wire mA output

Programmable ranges0…20 and 4…20 mA Direct or Inverted action
V-curve function, 100-0-100%20-0-20 mA
External loop supply3.5…30 V

Current output

Signal range0…23 mA (unipolar) -23…+23 mA (bipolar)
Current limit≤ 28 mA (unipolar) ± 28 mA (bipolar)
Load stability≤ 0.001% of span / 100 Ω
Response time, programmable0.0…60.0 s

Voltage output

Programmable signal ranges0/0.2…1; 0/1…5 ; 0/2…10; 1…0.2/0; 5…1/0; 10…2/0 V ±1, ±5 and ±10 V
Direct or Inverted action
V-curve function, 100-0-100%1-0-1, 5-0-5 and 10-0-10 V
Load (@ voltage output)≥ 500 kΩ
Response time, programmable0.0…60.0 s

Observed authority requirements

EMC2014/30/EU & UK SI 2016/1091
LVD2014/35/EU & UK SI 2016/1101
RoHS2011/65/EU & UK SI 2012/3032
EACTR-CU 020/2011

Approvals -4179 Universal AC / DC transmitter

c UL us, UL 508E248256
SILHardware assessed for use in SIL applications

NB

* / **For custom configurable signal ranges, general accuracy and EMC specifications are 0.3% of full scale

Additional information

Input

Current, Voltage

Output

Unipolar, Active / Passive Current

Power Supply

Universal

Mounting Type

DIN Rail

Function

Signal Converter

Advanced Features

Process Calibration, Simulation, Display Scaling, Front Configuration with Detachable Display 4510, 4511, 4512, Data Logging using 4512 Bluetooth Communication Enabler/Configurator, Password Protection

Origin

Denmark

Warranty

5 Years

Related Products

4116 Universal transmitter Peters SL - 4116 G3 Universal transmitter Peters SL 1307 PR Electronics buy from topline smart systems
-7%
PR 4116 Universal Transmitter

$246 Original price was: $246.$229Current price is: $229.

18 Sold
Fast Delivery
PR 4225 Universal fI ff Converter

$261$302

5 in stock
Fast Delivery