Description
PR 4179 Universal AC / DC transmitter from PR Electronics with mA/Voltage output.
Application
- The 0…5 AAC RMS range makes it possible to accurately measure a typical current transformer.
- The 0…300 VAC RMS range allows accurate supply voltage monitoring.
- The 4179 measures standard input ranges, and can be freely configured to customer-defined input range.
- Converts narrow AC current / voltage inputs to wide bipolar or unipolar outputs, e.g. 0…1 VAC RMS input = ±10 volt or 4…20 mA output with a minimum span of 0.5 AAC RMS or 0.5 VAC RMS.
- Configurable input limits control the output value for increased safety.
- The 4179 has been designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
- Suitable for the use in systems up to Performance Level “d” according to ISO-13849.
- The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
- Possibility of output safety feedback by selecting S4…20 mA output.
- The current output can drive up to 800 Ohms, with an adjustable response time of 0.0…60.0 seconds.
- Exceptional mA output load stability of <0.001% of span / 100 Ohm.
- Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
- Meets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.
- Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
- Excellent signal to noise ratio of > 60 dB.
Mounting / installation / programming – 4179 Universal AC / DC transmitter from PR Electronics
- Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
- Configuration, monitoring, 2-point process calibration and more are accomplished using PR’s 4500 series of detachable displays.
Data sheet
Environmental Conditions
Operating temperature | -20°C to +60°C |
Storage temperature | -20°C to +85°C |
Calibration temperature | 20…28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
Dimensions (HxWxD) w/ PR 4500 | 109 x 23.5 x 131 mm |
Weight approx. | 155 g |
Weight incl. 4501 / 451x (approx.) | 170 g / 185 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13…2.08 mm2 AWG 26…14 stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2…13.2 Hz | ±1 mm |
13.2…100 Hz | ±0.7 g |
Common specifications
Supply voltage, universal | 21.6…253 VAC, 50…60 Hz or 19.2…300 VDC |
Max. required power | 1.6 W |
Max. power dissipation – current measurement | 2.7 W |
Max. power dissipation – voltage measurement | 1.6 W |
Test voltage | 2.3 kVAC |
Working voltage | 250 VAC (reinforced) / 500 VAC (basic) |
Response time (0…90%, 100…10%) | < 0.75 s |
Programming | PR 4500 communication interfaces |
Signal dynamics, input | 20 bit |
Signal dynamics, output | 18 bit |
Signal / noise ratio | > 60 dB |
Output referred common mode rejection ratio | 0.02 ppm / VHz |
Accuracy | Better than 0.3% of selected range* |
EMC immunity influence | < ±0.5% of span* |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span* |
of span | = of selected standard range |
Input specifications – 4179 Universal AC / DC transmitter
Signal range | 0…5 AAC / 40…400 Hz |
Maximum input limit | 6.00 AAC @ 40°C |
Programmable measurement ranges | 0…0.5; 0…1; 0…2.5 & 0…5 AAC |
Custom configurable signal range | 0…5 AAC /40…400 Hz |
Min. measurement range (span) | 0.5 AAC |
Input resistance | < 0.042 Ω (incl. terminals) |
Signal range | 0…300 VAC / 40…400 Hz |
Programmable measurement ranges | 0…0.5, 0…1, 0…2.83, 0…5, 0…120, 0…230 & 0…300 VAC |
Custom configurable signal range | 0…300 VAC / 40…400 Hz |
Min. measurement range (span) | 0.5 VAC |
Input resistance | Nom. 3 MΩ || 100 pF |
Output specifications – 4179 Universal AC / DC transmitter
Programmable ranges | 0…20, 4…20 and S4…20 mA ±10 and ±20 mA
Direct or Inverted Action
|
Load (@ current output) | ≤ 800 Ω |
V-curve function, active signals, 100-0-100% | 20-0-20 mA |
Programmable ranges | 0…20 and 4…20 mA Direct or Inverted action
|
V-curve function, 100-0-100% | 20-0-20 mA |
External loop supply | 3.5…30 V |
Signal range | 0…23 mA (unipolar) -23…+23 mA (bipolar)
|
Current limit | ≤ 28 mA (unipolar) ± 28 mA (bipolar)
|
Load stability | ≤ 0.001% of span / 100 Ω |
Response time, programmable | 0.0…60.0 s |
Programmable signal ranges | 0/0.2…1; 0/1…5 ; 0/2…10; 1…0.2/0; 5…1/0; 10…2/0 V ±1, ±5 and ±10 V
Direct or Inverted action
|
V-curve function, 100-0-100% | 1-0-1, 5-0-5 and 10-0-10 V |
Load (@ voltage output) | ≥ 500 kΩ |
Response time, programmable | 0.0…60.0 s |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
LVD | 2014/35/EU & UK SI 2016/1101 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
Approvals -4179 Universal AC / DC transmitter
c UL us, UL 508 | E248256 |
SIL | Hardware assessed for use in SIL applications |
NB
* / ** | For custom configurable signal ranges, general accuracy and EMC specifications are 0.3% of full scale |