Description

3337 HART 7 loop powered Temperature Converter

Application

  • The 3337 temperature converter measures a standard Pt100, TC J and K temperature sensor, and provides an isolated passive analog current and HART signal output.
  • High 2 port isolation provides surge suppression and protects the control system from transients and noise.
  • The 3337 can be mounted in the safe area or in Zone 2 / Division 2 areas.
  • Approved for marine applications.

Technical characteristics

  • Flexibly loop powered by 6.2…35 VDC via connectors.
  • A 60 ms fast response time with simultaneous sensor error detection when selected.
  • Selectable internal/external CJC.
  • Excellent conversion accuracy in all available ranges, better than 0.05% of span.
  • Meeting the NAMUR NE21 recommendations, the 3337 provides top measurement performance in harsh EMC environments.
  • The device meets the NAMUR NE43 standard defining out of range and sensor error output values.
  • All terminals are protected against overvoltage and polarity error.
  • High galvanic isolation of 2.5 kVAC.
  • Excellent signal/noise ratio of > 60 dB.

Mounting / installation / programming

  • Selectable HART mode with HART 7 revision protocol enables extended device programming.
  • Selectable DIP-mode for easy configuration of more than 1000 factory calibrated measurement ranges with HART read only feature.
  • Selectable HART-mode to enable full HART read-write capability.
  • The narrow 6.1 mm housing allows up to 163 units to be mounted per meter of DIN rail, without any air gap between units.
  • Wide ambient temperature range of -25…+70°C.

Data sheet & Manuals


Data sheet

Manuals

Environmental Conditions

Operating temperature-25°C to +70°C
Storage temperature-40°C to +85°C
Calibration temperature20…28°C
Relative humidity< 95% RH (non-cond.)
Protection degreeIP20
Installation inPollution degree 2 & meas. / overvoltage cat. II

Mechanical specifications

Dimensions (HxWxD)113 x 6.1 x 115 mm
Weight approx.70 g
DIN rail typeDIN EN 60715/35 mm
Wire size0.13…2.5 mm2 / AWG 26…12 stranded wire
Screw terminal torque0.5 Nm
VibrationIEC 60068-2-6
2…25 Hz±1.6 mm
25…100 Hz±4 g

Common specifications

Supply

Supply voltage6.2…35 VDC
Max. required power0.80 W
Internal power dissipation22 mW…0.8 W

Isolation voltage

Isolation voltage, test / working2.5 kVAC / 300 VAC (reinforced)
Zone 2 / Div. 2250 VAC

Response time

HART mode, (0…90%, 100…10%)60 ms…60 s, programmable
DIP mode, (0…90%, 100…10%)< 60 ms
Voltage drop6.2 VDC
Signal / noise ratioMin. 60 dB
ProgrammingDIP-switches
Signal dynamics, input23 bit
Signal dynamics, output18 bit
EMC immunity influence< ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst< ±1% of span
Incorrect DIP-switch setting identification3.5 mA

Input specifications

RTD input

Temperature range, Pt100-200…+850°C
Accuracy: the greater ofBetter than 0.05% of span or 0.1°C
Temperature coefficient: the greater of0.02°C/°C or ≤ ±0.01%/°C
Sensor current< 150 µA
Sensor cable resistance< 50 Ω per wire
Effect of sensor cable resistance (3-/4-wire)< 0.002 Ω / Ω
Sensor error detectionYes – selectable via DIP-switch
Broken sensor detection> 800 Ω
Shorted sensor detection< 18 Ω

TC input

Temperature range, TC J-100…+1200°C
Temperature range, TC K-180…+1372°C
Accuracy: the greater ofBetter than 0.05% of span or 0.5°C
Temperature coefficient: the greater of0.1°C/°C or ≤ ±0.01%/°C
Sensor cable resistance< 5 kΩ per wire
Cold junction compensation (CJC): Accuracy @ external Pt100 inputBetter than ±0.15°C
Cold junction compensation (CJC): Accuracy @ internal CJCBetter than ±2.5°C
Internal CJC error detectionYes
External CJC error detectionYes – selectable via DIP-switch
Open Thermocouple detectionYes – selectable via DIP-switch

Output specifications

Common output specifications

Updating time10 ms

Current output

Programmable signal ranges4…20 and 20…4 mA
Load (@ current output)≤ (Vsupply – 6.2) / 0.023 [Ω]
Load stability≤ 0.01% of span / 100 Ω
Sensor error indication3.5 mA or 23 mA / acc. to NAMUR NE43 or OFF
HART protocol revisionsHART 7

I.S. / Ex marking

ATEXII 3 G Ex ec IIC T4 Gc
IECExEx ec IIC T4 Gc
FM, USCl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4
FM, CACl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4
EAC Ex2Ex nA IIC T4 Gc X

Observed authority requirements

EMC2014/30/EU & UK SI 2016/1091
LVD2014/35/EU & UK SI 2016/1101
ATEX2014/34/EU & UK SI 2016/1107
RoHS2011/65/EU & UK SI 2012/3032
EACTR-CU 020/2011
EAC ExTR-CU 012/2011

Approvals

ATEXKEMA 10ATEX0147 X
IECExKEM 10.0068X
UKEXDEKRA 21UKEX0055X
c FM usFM17US0004X / FM17CA0003X
c UL us, UL 61010-1E314307
EAC ExEAEU KZ 7500361.01.01.08756
DNV MarineTAA00001RW

3337 HART 7 Loop Powered Temperature Converter by PR Electronics: Excellence in Precision Control

The 3337 HART 7 Loop Powered Temperature Converter from PR Electronics is a game-changer for industrial temperature measurement. Designed with cutting-edge technology and HART 7 compatibility, this versatile device offers unmatched accuracy and advanced communication capabilities for modern process industries.

Key Features of the 3337 HART 7 Temperature Converter:

  • HART 7 Protocol Compatibility: Seamlessly integrates with industry-standard communication systems for real-time data access and control.
  • Loop-Powered Design: Reduces wiring complexity and provides power efficiency, making it perfect for demanding industrial environments.
  • Universal Sensor Input: Compatible with a wide range of temperature sensors, including Pt100, Pt1000, and thermocouples, ensuring adaptability for diverse applications.
  • High Accuracy and Stability: Guarantees precise temperature readings, maintaining process integrity and performance.
  • Rugged and Reliable: Engineered to withstand harsh operating conditions, ensuring long-term durability.

Why Choose the 3337 HART 7 Loop Powered Temperature Converter?

PR Electronics has long been a trusted leader in the field of industrial process instrumentation, and the 3337 HART 7 Converter exemplifies their commitment to innovation and quality. With its advanced HART 7 communication protocol, this device not only ensures accurate temperature conversion but also offers enhanced diagnostics, simplifying maintenance and improving overall system efficiency.

Whether you’re working in petrochemical, pharmaceutical, or energy industries, this converter is designed to meet your needs for precision and reliability in temperature monitoring.

Take Your Process to the Next Level

Elevate your industrial setup with the 3337 HART 7 Loop Powered Temperature Converter by PR Electronics. Explore the benefits of HART 7 communication, enhanced accuracy, and robust design. Reach out to PR Electronics or an authorized distributor to learn more about integrating this state-of-the-art solution into your system.

Related Products

PR 4225 Universal fI ff Converter

$261$302

5 in stock
Fast Delivery
4116 Universal transmitter Peters SL - 4116 G3 Universal transmitter Peters SL 1307 PR Electronics buy from topline smart systems
-7%
PR 4116 Universal Transmitter

$246 Original price was: $246.$229Current price is: $229.

18 Sold
Fast Delivery