Description
PR 3333 Pt100 converter loop powered – PR Electronics
Application
- The 3333 temperature converter measures a standard 2-, 3- or 4-wire Pt100 temperature sensor, and provides a passive analog current output signal.
- The 3333 can be mounted in the safe area or in Zone 2 / Division 2 areas.
- Approved for marine applications.
Technical characteristics
- Flexibly loop powered by 3.3…35 VDC via connectors.
- < 30 ms fast response time with simultaneous sensor error detection when selected.
- Selectable 300 ms response time when signal dampening is needed.
- High conversion accuracy in all available ranges, better than 0.1% of span.
- Meeting the NAMUR NE21 recommendations, the 3333 provides top measurement performance in harsh EMC environments.
- The device meets the NAMUR NE43 standard defining out of range and sensor error output values.
- All terminals are protected against overvoltage and polarity error.
- Excellent signal/noise ratio of > 60 dB.
Mounting / installation / programming
- Selectable DIP-settings for easy configuration of more than 1000 factory calibrated measurement ranges.
- The narrow 6.1 mm housing allows up to 163 units to be mounted per meter of DIN rail, without any air gap between units.
- Wide ambient temperature range of -25…+70°C.
Data sheet & Manuals
Data sheet
Manuals
Environmental Conditions
Operating temperature | -25°C to +70°C |
Storage temperature | -40°C to +85°C |
Calibration temperature | 20…28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
Dimensions (HxWxD) | 113 x 6.1 x 115 mm |
Weight approx. | 70 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13…2.5 mm2 / AWG 26…12 stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2…25 Hz | ±1.6 mm |
25…100 Hz | ±4 g |
Common specifications
Supply | |
Supply voltage | 3.3…35 VDC |
Max. required power | 0.80 W |
Internal power dissipation | 12 mW…0.8 W |
Response time | |
Response time (0…90%, 100…10%) | < 30 ms / 300 ms (selectable) |
Voltage drop | 3.3 VDC |
Signal / noise ratio | Min. 60 dB |
Programming | DIP-switches |
Signal dynamics, input | 23 bit |
Signal dynamics, output | 18 bit |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Incorrect DIP-switch setting identification | 3.5 mA |
Input specifications
RTD input | |
Temperature range, Pt100 | -200…+850°C |
Min. measurement range (span) | 10°C |
Accuracy: the greater of | Better than 0.1% of span or 0.2°C |
Temperature coefficient: the greater of | 0.02°C/°C or ≤ ±0.01%/°C |
Sensor current | < 150 µA |
Sensor cable resistance | < 50 Ω per wire |
Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
Sensor error detection | Yes – selectable via DIP-switch |
Broken sensor detection | > 800 Ω |
Shorted sensor detection | < 18 Ω |
Output specifications
Common output specifications | |
Updating time | 10 ms |
Current output | |
Programmable signal ranges | 4…20 and 20…4 mA |
Load (@ current output) | ≤ (Vsupply – 3.3) / 0.023 [Ω] |
Load stability | ≤ 0.01% of span / 100 Ω |
Sensor error indication | 3.5 mA or 23 mA / acc. to NAMUR NE43 or OFF |
I.S. / Ex marking
ATEX | II 3 G Ex ec IIC T4 Gc |
IECEx | Ex ec IIC T4 Gc |
FM, US | Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4 |
FM, CA | Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4 |
EAC Ex | 2Ex nA IIC T4 Gc X |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
LVD | 2014/35/EU & UK SI 2016/1101 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
ATEX | KEMA 10ATEX0147 X |
IECEx | KEM 10.0068X |
UKEX | DEKRA 21UKEX0055X |
c FM us | FM17US0004X / FM17CA0003X |
c UL us, UL 61010-1 | E314307 |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
DNV Marine | TAA00001RW |
3333 Pt100 Converter Loop Powered by PR Electronics: Precision at Its Best
When it comes to achieving accurate temperature measurements in industrial applications, the 3333 Pt100 Converter Loop Powered by PR Electronics is the go-to solution for engineers and technicians around the globe. Designed for seamless integration, this innovative device offers unparalleled performance, reliability, and ease of use.
Key Features of the 3333 Pt100 Converter Loop Powered:
- Loop-Powered Design: Simplify installations with a streamlined, loop-powered operation that eliminates the need for external power sources.
- Superior Accuracy: Ensures precise temperature conversions for Pt100 sensors, catering to industries where accuracy is non-negotiable.
- Compact Build: Engineered for space efficiency, allowing easy placement in tight industrial setups.
- Durable & Reliable: Built to withstand harsh environments, ensuring consistent performance even under challenging conditions.
Why Choose the 3333 Pt100 Converter from PR Electronics?
PR Electronics is synonymous with cutting-edge innovation and quality. The 3333 Pt100 Converter Loop Powered is a testament to their dedication to designing tools that enhance efficiency and deliver dependable performance. Whether you’re working in chemical processing, energy production, or manufacturing, this converter empowers you to maintain optimal temperature control and operational excellence.
Optimize Your System Today
Discover how the 3333 Pt100 Converter Loop Powered by PR Electronics can redefine precision in temperature measurement for your industrial setup. Contact PR Electronics or your local distributor to learn more and take the first step toward enhanced performance.